| Detail | ||||||
| General | ReactionResponse Network | Let-GoResponse Network | Unweighted Burn Hazard Response Network | |||
| Equivalent network component values: | Complies with values specified in IEC 990 (excluding fuse) | |||||
| Equivalent measuring instrument load: | 1 M_ - 10pF | 1 M_ - 62 pF | 1 M_ - 1 pF | |||
| Ranges | 0.3, 1, 3, 10 M.I.U. | 0.3, 1, 3, 10 M.I.U. | 0-100 mA RMS | |||
| Current accuracy: | ±2% F.S. @ 60 Hz | |||||
| Meter measurement method: | True RMS | |||||
| Meter frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||||
| DC to 1 Hz | Pointer shall track within 5% of peak | |||||
| 2Hz to 19Hz (Accuracy not supported) | ||||||
| 20 Hz to 200 KHz | ±2% F.S. | ±2.5% of F.S. | ±2% F.S. | |||
| 200 KHz to 1 MHz | ±2% F.S. | ±2.5% F.S | ±5% F.S. | |||
| Output sensitivity: | Full scale meter indication equals 1V RMS (Measured with a 1 M_, 12 pF load) | |||||
| Output accuracy: | ±2% of reading @ 60 Hz | |||||
| Output frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||||
| DC to 50Hz | ±2% of reading | |||||
| 50 Hz to 100 KHz | ±2.5% of reading | ±2% /-3% of reading | ±2% of reading | |||
| 100 kHz to 1 MHz | ±5% of reading | |||||
| Voltmeter range: | 0-300 V (AC or DC) | |||||
| Voltmeter accuracy: DC to 1 Hz | Pointer shall track within 5% of peak | |||||
| 2Hz to 19Hz (Accuracy not supported) | ||||||
| 20 Hz to 1KHz _ | 3% F.S. @ 60 Hz (Add _1% for every additional 100Hz) | |||||
| Voltmeter frequency response: | DC to 1 KHz | |||||
| Power requirements | (2) 9V (NEDA 1604A) batteries | |||||
| Physical | 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input | |||||
| Environmental | 27°C _2° C, 70% non condensing relative humidity. Outside this range derate by 10% per °C | |||||
| Maximum operating range | 0° to 40° C | |||||